Blend into adjacent panel - 45 LVOC VOC 45 Line 1. Cleaning step Clean carefully with cleaner 70-45 Use wipe on wipe off method 2. Preparation steps: Tag cloth the area to be painted 3. Mixing ratio: Basecoat (45-) 100% 45-R45 Diluter 70% 4. Application first coat Spray gun HVLP 1.4 pressure 29.0 psi (2.0 bar) Spray 1 wet coat on the fender Flash off 5. Mixing blend in clear: 6. Application method blend in clear Spray full wet coat on door, until 4in (10 cm) of adjacent panels No flash off 7. Mixing ratio: Basecoat 100% 45-R45 Diluter 70% 8. Application method second coat Spray gun HVLP 1.4 pressure 29.0 psi (2.0 bar) Spray second coat on wing Reduce pressure between 11.6 - 21.8 psi (0.8 - 1.5 bar) and blend in the door 9. Application method Flash off until matte door and fender 10. Mist coat Apply mist coat over repaired are Spray gun distance approx. 12 in (30 cm) from object Flash off Ready for clear coat Repair Steps Basecoat/ Topcoat Start working with baslac today. It just makes sense. Contact us Get in touch with your local baslac dealer now and start working smarter. Find a dealer near you